• Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
  • Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
  • Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
  • Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
  • Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery

Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery

Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting
Nominal Voltage: 12V
Discharge Rate: Low Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FTG200-12
Installation
Packaged
Rechargeable
Chargeable
Approx Weight
60kg
Unit/Carton
1
Carton Dimension
570*135*341mm
Transport Package
Carton/ Pallet
Specification
560*125*315mm
Trademark
kptgu
Origin
China
HS Code
8507200000
Production Capacity
600 PCS/Day

Product Description

12V-200AH Front Terminal Maitanance Free Lead Acid Battery
Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
Specification Type
Model NO. Volts Capacity(AH) Approx Dimension(mm) Approx Weight(kg) Unit/carton(pcs) Carton Dimension(mm)
20hrs rate L W H
FTG50-12 12 50 290.9 105.8 231 16 1 300*115*256
FTG55-12 12 55 290.9 105.8 231 17 1 300*115*256
FTG70-12 12 70 560.6 114.5 187 25 1 570*124*212
FTG75-12 12 75 560.6 114.5 187 26 1 570*124*212
FTG80-12 12 80 409.1 110 294.6 26 1 419*125*319
FTG100-12 12 100 409.1 110 294.6 31 1 419*125*319
FTG105-12 12 105 507 110 231 34 1 517*125*256
FTG120-12 12 120 565 110 296 39.5 1 595*125*325
FTG125-12 12 125 565 110 296 41 1 595*125*325
FTG150-12 12 150 565 110 296 45 1 595*125*325
FTG160-12 12 160 560 125 315 46 1 570*135*341
FTG170-12 12 170 560 125 315 52 1 570*135*341
FTG180-12 12 180 560 125 315 55 1 570*135*341
FTG200-12 12 200 560 125 315 60 1 570*135*341
Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
Battery connection

Only batteries or battery packs with the same actual capacity can be used in series.
The connection part shall be tight to prevent sparks; in case of poor contact, the contact surtace can be cleaned with soda water.Only batteries or battery groups with the same actual voltage can be used in parallel,
The positive and negative poles shall not be reversed or short circuited.
The batteries of the battery pack shall be separated by more than 10 mm to facllitate heat dissipation.

Battery charging
Floating charge (limit voltage, control current) use: charging voltage2.20-2.30V single cell (25 C).
When trickle current is used, the floating charge current of the battery is adjusted to less than 2mAl ah;
Temperature compensation, the temperature compensation coefficient of each monomer is 3MV c.(based on20 'ºC)
Cyclic use (stop when fully charged, charge when fully discharged):charging voltage 2.35-2.45v single call maximum power.The flow shall not be greater than 25%of the nominal capacity;
Note:the battery shall not be used in closed or high temperatdre environment, and shall be kept away from the fire source.

Storage and installation
1.For batteries not put into use, the connecting wire shall be removed, the pole sheath shall be covered and wiped clean;
2.Maintain and charge the battery every three months. T he charging method is limited current and constant voltageMethod: the initial charging current is 0.1CA, and the charging volltage is 24V single cell (at 25 c);
3.The battery shall be stored in a dry and ventilated place, away from direct sunlight and heat source.
4.When handling the battery, the force shall be even, and the stress part is the shell artof the batfery to avoid damaging the pole;
5.Insulating tools shall be used during installation to prevent electric shock.

Points to note

1.When the batlery is discharged from the factory. do not attempt to disassemble the battery to avoid danger .if the battery shells damaged accidentally ln case of contact with sulfuric acid, please wash with plenty of clear water immediately, and see a doctor immediatly if necessary
2.Do not mix the old and new batteries;
3.Do not use battery in sealed container;
4.The battery shall have a complete resume , including factory date, installation date, operation record, etc;
5.Regularly (once a year) check whether the connecting wire is loose. lf it is loose, fasten it;
6.Wipe the battery regularly (once every three months) with soft fabric to keep the battery clean;
7.Do not use organic solvents to clean the battery.
8.Pay attention to the battery spacing to prevent salt bridge.
Front Terminal 12V-200ah Solar Power Supply System High-End Storage BatteryFront Terminal 12V-200ah Solar Power Supply System High-End Storage Battery
 
 
Front Terminal 12V-200ah Solar Power Supply System High-End Storage Battery


 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
10
Year of Establishment
2021-04-13