2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery

Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting
Nominal Voltage: 2V
Discharge Rate: Low Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Customization:

Contact Supplier

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
KPT600-2
Installation
Packaged
Rechargeable
Chargeable
Warrenty
3 Years
Transport Package
Carton/ Pallet
Specification
301*175*364mm
Trademark
kptgu
Origin
China
HS Code
8507200000
Production Capacity
600 PCS/Day

Product Description


                2V 600ah Rechargeable battery Valve-Operated Lead Acid UPS Battery

2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery
Specification Type
Model No Votage Capacity(AH) Unit Dimension(mm) MOQ(PCS)
KPT100-2 2 100 171*72*205 200
KPT150-2 2 150 172*102*239 100
KPT200-2 2 200 173*111*362 80
KPT300-2 2 300 171*150*344 60
KPT400-2 2 400 211*175*362 60
KPT500-2 2 500 241*172*363 30
KPT600-2 2 600 301*175*364 30
KPT800-2 2 800 410*175*363 20
KPT1000-2 2 1000 477*174*361 15
2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery 2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery
Battery connection

Only batteries or battery packs with the same actual capacity can be used in series.
The connection part shall be tight to prevent sparks; in case of poor contact, the contact surtace can be cleaned with soda water.Only batteries or battery groups with the same actual voltage can be used in parallel,
The positive and negative poles shall not be reversed or short circuited.
The batteries of the battery pack shall be separated by more than 10 mm to facllitate heat dissipation.

Battery charging
Floating charge (limit voltage, control current) use: charging voltage 2.20-2.30V single cell (25 C).
When trickle current is used, the floating charge current of the battery is adjusted to less than 2mAl ah;
Temperature compensation, the temperature compensation coefficient of each monomer is 3MV c.(based on20 'ºC)
Cyclic use (stop when fully charged, charge when fully discharged):charging voltage 2.35-2.45v single call maximum power.The flow shall not be greater than 25%of the nominal capacity;
Note:the battery shall not be used in closed or high temperatdre environment, and shall be kept away from the fire source.

Storage and installation
1.For batteries not put into use, the connecting wire shall be removed, the pole sheath shall be covered and wiped clean;
2.Maintain and charge the battery every three months. T he charging method is limited current and constant voltageMethod: the initial charging current is 0.1CA, and the charging volltage is 24V single cell (at 25 c);
3.The battery shall be stored in a dry and ventilated place, away from direct sunlight and heat source.
4.When handling the battery, the force shall be even, and the stress part is the shell artof the batfery to avoid damaging the pole;
5.Insulating tools shall be used during installation to prevent electric shock.

Points to note

1.When the batlery is discharged from the factory. do not attempt to disassemble the battery to avoid danger .if the battery shells damaged accidentally ln case of contact with sulfuric acid, please wash with plenty of clear water immediately, and see a doctor immediatly if necessary
2.Do not mix the old and new batteries;
3.Do not use battery in sealed container;
4.The battery shall have a complete resume , including factory date, installation date, operation record, etc;
5.Regularly (once a year) check whether the connecting wire is loose. lf it is loose, fasten it;
6.Wipe the battery regularly (once every three months) with soft fabric to keep the battery clean;
7.Do not use organic solvents to clean the battery.
8.Pay attention to the battery spacing to prevent salt bridge.
2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery 2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery 2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery
 
 
2V 600ah Rechargeable Battery Valve-Operated Lead Acid UPS Battery


 
 

Send your message to this supplier

*From:
*To:
avatar Miss Doris
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now